6/24/2018
Posted by 
Unisphere Server Software Download Rating: 7,7/10 8619votes

Configure below parameters; • Real time Interval – Required for real time performance overview monitoring • Archive Interval – After this much of seconds it is going to pull out data and write into the NAR file. • Periodic Archiving – Make sure this option is checked. This option helps to create periodic new NAR files. • As per, each NAR or NAZ file will contain 155 polling intervals of data called data points. Therefore if we set the Archive Interval to 120secs, it will create new NAR file in each 5hrs 10mins (155 x 120sec = 18600sec/60sec=310min/60min=5hr10min). If we set the interval to 300secs, it will create new NAR file in each 12hr55min • Once each NAR file is full it creates another file.

Having said that if we have bigger SAN environment it make take more time to pull the data from SP. So default 120 value may not work here, we may like to increase to 300sec. Vickers Manual. But higher intervals may miss key details about heavily loaded drives in a Pool. So In case of VNX while doing performance troubleshooting it is recommended to set Archive Interval to 60secs & no more than 300sec. • Real Time interval is recommended to set lower or equal to archive interval because you will be watching real time graphs in Unisphere. • Before we change the archival time it is recommended to stop the logging, hence it will dump all data to NAR file and close that. Template Undangan Pernikahan Unik Cdr. And while you start with new time period it will start with new interval values. Buensoft Crack on this page.

Unisphere Vnx Client DownloadUnisphere Server Software Download